247 research outputs found

    Artificial Intelligence and Interstitial Lung Disease: Diagnosis and Prognosis.

    Get PDF
    Interstitial lung disease (ILD) is now diagnosed by an ILD-board consisting of radiologists, pulmonologists, and pathologists. They discuss the combination of computed tomography (CT) images, pulmonary function tests, demographic information, and histology and then agree on one of the 200 ILD diagnoses. Recent approaches employ computer-aided diagnostic tools to improve detection of disease, monitoring, and accurate prognostication. Methods based on artificial intelligence (AI) may be used in computational medicine, especially in image-based specialties such as radiology. This review summarises and highlights the strengths and weaknesses of the latest and most significant published methods that could lead to a holistic system for ILD diagnosis. We explore current AI methods and the data use to predict the prognosis and progression of ILDs. It is then essential to highlight the data that holds the most information related to risk factors for progression, e.g., CT scans and pulmonary function tests. This review aims to identify potential gaps, highlight areas that require further research, and identify the methods that could be combined to yield more promising results in future studies

    Mass hierarchy discrimination with atmospheric neutrinos in large volume ice/water Cherenkov detectors

    Full text link
    Large mass ice/water Cherenkov experiments, optimized to detect low energy (1-20 GeV) atmospheric neutrinos, have the potential to discriminate between normal and inverted neutrino mass hierarchies. The sensitivity depends on several model and detector parameters, such as the neutrino flux profile and normalization, the Earth density profile, the oscillation parameter uncertainties, and the detector effective mass and resolution. A proper evaluation of the mass hierarchy discrimination power requires a robust statistical approach. In this work, the Toy Monte Carlo, based on an extended unbinned likelihood ratio test statistic, was used. The effect of each model and detector parameter, as well as the required detector exposure, was then studied. While uncertainties on the Earth density and atmospheric neutrino flux profiles were found to have a minor impact on the mass hierarchy discrimination, the flux normalization, as well as some of the oscillation parameter (\Delta m^2_{31}, \theta_{13}, \theta_{23}, and \delta_{CP}) uncertainties and correlations resulted critical. Finally, the minimum required detector exposure, the optimization of the low energy threshold, and the detector resolutions were also investigated.Comment: 23 pages, 16 figure

    Coronary CT FFR vs Invasive Adenosine and Dobutamine FFR in a Right Anomalous Coronary Artery.

    Get PDF
    We present the management of an anomalous coronary artery originating from the opposite sinus of Valsalva with comprehensive diagnostic workup including noninvasive coronary computed tomography (CT) derived fractional flow reserve (FFR) and invasive dobutamine-volume challenge-FFR/intravascular ultrasound. After surgical operation, treatment success was quantified by anatomical and functional analysis in postoperative CT. (Level of Difficulty: Advanced.)

    Avoiding the Intercostal Arteries in Percutaneous Thoracic Interventions.

    Get PDF
    The purpose of this study was to define relevant intercostal artery (ICA) anatomy potentially impacting the safety of thoracic percutaneous interventional procedures. An ICA abutting the upper rib and running in the subcostal groove was defined as the lowest risk zone for interventions requiring a supracostal needle puncture. A theoretical high-risk zone was defined by the ICA coursing in the lower half of the intercostal space (ICS), and a theoretical moderate-risk zone was defined by the ICA coursing below the subcostal groove but in the upper half of the ICS. Arterial phase computed tomography data from 250 patients were analyzed, revealing demographic variability, with high-risk zones extending more laterally with advancing age and with more cranial ribs. Overall, within the 97.5th percentile, an ICS puncture >7-cm lateral to the spinous process incurs moderate risk and >10-cm lateral incurs the lowest risk

    Reproducibility and its confounders of CMR feature tracking myocardial strain analysis in patients with suspected myocarditis.

    Get PDF
    OBJECTIVES Cardiovascular magnetic resonance feature tracking (CMR-FT) is an emerging technique for assessing myocardial strain with valuable diagnostic and prognostic potential. However, the reproducibility of biventricular CMR-FT analysis in a large cardiovascular population has not been assessed. Also, evidence of confounders impacting reader reproducibility for CMR-FT in patients is unknown and currently limits the clinical implementation of this technique. METHODS From a dual-center database of patients referred to CMR for suspected myocarditis, 125 patients were randomly selected to undergo biventricular CMR-FT analysis for 2-dimensional systolic and diastolic measures, with additional 3-dimensional analysis for the left ventricle. All image analysis was replicated by a single reader and by a second reader for intra- and inter-reader analysis (Circle Cardiovascular Imaging). Reliability was tested with intraclass correlation (ICC) tests, and the impact of imaging confounders on agreement was assessed through multivariable analysis. RESULTS Left and right ventricular ejection fractions were reduced in 34% and 37% of the patients, respectively. Good to excellent reliability was shown for 2D (all ICC > 0.85) and 3D (all ICC > 0.70) peak strain and early diastolic strain rate for both ventricles in longitudinal orientation as well as circumferential orientations for the left ventricle. An increased slice number improved agreement while the presence of pericardial effusion compromised diastolic strain rate agreement, and arrhythmia compromised right ventricular agreement. CONCLUSION In a large clinical cohort, we could show CMR-FT yields excellent inter-reader and intra-reader reproducibility. Multi-parametric CMR-FT of the right and left ventricles appears to be a robust tool in cardiovascular patients referred to CMR. CLINICAL TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT03470571, NCT04774549. Key Points • Cardiovascular magnetic resonance feature tracking (CMR-FT) is an emerging technique to measure myocardial strain in cardiovascular patients referred for CMR; however, the evaluation of its reproducibility in a large cohort has not yet been performed. • In a large clinical cohort, CMR-FT yields excellent inter-reader and intra-reader reproducibility for both left and right ventricular systolic and diastolic parameters. • Arrhythmia and pericardial effusion compromise agreement of select FT parameters, but poor ejection fraction does not

    828 kHz retinal imaging with an 840 nm Fourier domain mode locked laser

    Get PDF
    This paper presents a Fourier domain mode locked (FDML) laser centered around 840 nm. It features a bidirectional sweep repetition rate of 828 kHz and a spectral bandwidth of 40 nm. An axial resolution of ∼9.9 μm in water and a 1.4 cm sensitivity roll-off are achieved. Utilizing a complex master-slave (CMS) recalibration method and due to a sufficiently high sensitivity of 84.6 dB, retinal layers of the human eye in-vivo can be resolved during optical coherence tomography (OCT) examination. The developed FDML laser enables acquisition rates of 3D-volumes with a size of 200 × 100 × 256 voxels in under 100 milliseconds. Detailed information on the FDML implementation, its challenging design tasks, and OCT images obtained with the laser are presented in this paper

    Diagnostic performance of quantitative coronary artery disease assessment using computed tomography in patients with aortic stenosis undergoing transcatheter aortic-valve implantation.

    Get PDF
    BACKGROUND Computed tomography angiography (CTA) is a cornerstone in the pre- transcatheter aortic valve replacement (TAVI) assessment. We evaluated the diagnostic performance of CTA and coronary artery calcium score (CACS) for CAD evaluation compared to invasive coronary angiography in a cohort of TAVI patients. METHODS In consecutive TAVI patients without prior coronary revascularization and device implants, CAD was assessment by quantitative analysis in CTA. (a) Patients with non-evaluable segments were classified as obstructive CAD. (b) In patients with non-evaluable segments a CACS cut-off of 100 was applied for obstructive CAD. The reference standard was quantitative invasive coronary angiography (QCA, i.e. ≥ 50% stenosis). RESULTS 100 consecutive patients were retrospectively included, age was 82.3 ± 6.5 years and 30% of patients had CAD. In 16% of the patients, adequate visualization of the entire coronary tree (all 16 segments) was possible with CTA, while 84% had at least one segment which was not evaluable for CAD analysis due to impaired image quality. On a per-patient analysis, where patients with low image quality were classified as CAD, CTA showed a sensitivity of 100% (95% CI 88.4-100.0), specificity of 11.4% (95% CI 5.1-21.3), PPV of 32.6% (95% CI 30.8-34.5), NPV of 100% and diagnostic accuracy of 38% (95% CI 28.5-48.3) for obstructive CAD. When applying a combined approach of CTA (in patients with good image quality) and CACS (in patients with low image quality), the sensitivity and NPV remained at 100% and obstructive CAD could be ruled out in 20% of the TAVI patients, versus 8% using CTA alone. CONCLUSION In routinely acquired pre-TAVI CTA, the image quality was insufficient in a high proportion of patients for the assessment of the entire coronary artery tree. However, when adding CACS in patients with low image quality to quantitative CTA assessment in patients with good image quality, obstructive CAD could be ruled-out in 1/5 of the patients and may therefore constitute a strategy to streamline pre-procedural workup, and reduce risk, radiation and costs in selected TAVI patients without prior coronary revascularization or device implants

    Reproducibility of 4D cardiac computed tomography feature tracking myocardial strain and comparison against speckle-tracking echocardiography in patients with severe aortic stenosis.

    Get PDF
    BACKGROUND Myocardial strain is an established parameter for the assessment of cardiac function and routinely derived from speckle tracking echocardiography (STE). Novel post-processing tools allow deformation imaging also by 4D cardiac computed tomography angiography (CCT). This retrospective study aims to analyze the reproducibility of CCT strain and compare it to that of STE. METHODS Left (LV) and right ventricular (RV), and left atrial (LA) ejection fraction (EF), dimensions, global longitudinal (GLS), circumferential (GCS) and radial strain (GRS) were determined by STE and CCT feature tracking in consecutive patients with severe aortic stenosis evaluated for transcatheter aortic valve implantation. RESULTS 106 patients (mean age 79.9 ​± ​7.8, 44.3% females) underwent CCT at a median of 3 days (IQR 0-28 days) after STE. In CCT, strain measures showed good to excellent reproducibility (intra- and inter-reader intraclass correlation coefficient ≥0.75) consistently in the LV, RV and LA. In STE, only LV GLS and LA GLS yielded good reproducibility, whereas LV GCS and LV GRS showed moderate, and RV GLS and free wall longitudinal strain (FWLS) poor reproducibility. Agreement between CCT and STE was strong for LV GLS only, while other strain features displayed moderate (LV GCS, LA GLS) or weak (LV GRS, RV GLS and FWLS) inter-modality correlation. CONCLUSION LV, RV and LA CCT strain assessments were highly reproducible. While a strong agreement to STE was found for LV GLS, inter-modality correlation was moderate or weak for LV GCS, LV GRS, and RV and LA longitudinal strain, possibly related to poor reproducibility of STE measurements

    Diagnostic performance of cardiac magnetic resonance segmental myocardial strain for detecting microvascular obstruction and late gadolinium enhancement in patients presenting after a ST-elevation myocardial infarction.

    Get PDF
    Background Microvascular obstruction (MVO) and Late Gadolinium Enhancement (LGE) assessed in cardiac magnetic resonance (CMR) are associated with adverse outcome in patients with ST-elevation myocardial infarction (STEMI). Our aim was to analyze the diagnostic performance of segmental strain for the detection of MVO and LGE. Methods Patients with anterior STEMI, who underwent additional CMR were enrolled in this sub-study of the CARE-AMI trial. Using CMR feature tracking (FT) segmental circumferential peak strain (SCS) was measured and the diagnostic performance of SCS to discriminate MVO and LGE was assessed in a derivation and validation cohort. Results Forty-eight STEMI patients (62 ± 12 years old), 39 (81%) males, who underwent CMR (i.e., mean 3.0 ± 1.5 days) after primary percutaneous coronary intervention (PCI) were included. All patients presented with LGE and in 40 (83%) patients, MVO was additionally present. Segments in all patients were visually classified and 146 (19%) segments showed MVO (i.e., LGE+/MVO+), 308 (40%) segments showed LGE and no MVO (i.e., LGE+/MVO-), and 314 (41%) segments showed no LGE (i.e., LGE-). Diagnostic performance of SCS for detecting MVO segments (i.e., LGE+/MVO+ vs. LGE+/MVO-, and LGE-) showed an AUC = 0.764 and SCS cut-off value was -11.2%, resulting in a sensitivity of 78% and a specificity of 67% with a positive predictive value (PPV) of 30% and a negative predictive value (NPV) of 94% when tested in the validation group. For LGE segments (i.e., LGE+/MVO+ and LGE+/MVO- vs. LGE-) AUC = 0.848 and SCS with a cut-off value of -13.8% yielded to a sensitivity of 76%, specificity of 74%, PPV of 81%, and NPV of 70%. Conclusion Segmental strain in STEMI patients was associated with good diagnostic performance for detection of MVO+ segments and very good diagnostic performance of LGE+ segments. Segmental strain may be useful as a potential contrast-free surrogate marker to improve early risk stratification in patients after primary PCI
    • …
    corecore